NSP-5
A general purpose column for semi volatiles, pesticides, PCB congeners and essential oils, etc.
Stationary Phase Properties:
- non-polar, low phenyl content
- immobilized and chemically bonded
- temperature limits -0°C to 360°C
- low column bleed
The NSP-5 columns are a highly selective, highly stable equivalent of the conventional 5% diphenyl/95% dimethyl polysiloxane stationary phase columns. These columns essentially provide boiling point elution order - with the added advantage of enhanced retention of aromatic and polar compounds resulting in improved overall selectivity.
It is a general purpose column for semi volatiles, pesticides, PCB congeners and essential oils with enhanced selectivity for selected groups of compounds such as isomeric polycyclic aromatic hydrocarbons.
The columns are highly stable with a maximum operating temperature limit (MOTL) of 360°C. They demonstrate unmatched selectivity when compared to conventional stationary phase columns. The NSP-5 columns show ultra low bleed at the retention times of heavier compounds, such as heavier PAH’s.
Due to high temperature stability, these columns can be used in isothermal or temperature program modes up to 360°C. The MOTL decreases with increase in column length and film thickness.
Application Chromatograms
Stationary Phase Properties:
- non-polar, low phenyl content
- immobilized and chemically bonded
- temperature limits -0°C to 360°C
- low column bleed
The NSP-5 columns are a highly selective, highly stable equivalent of the conventional 5% diphenyl/95% dimethyl polysiloxane stationary phase columns. These columns essentially provide boiling point elution order - with the added advantage of enhanced retention of aromatic and polar compounds resulting in improved overall selectivity.
It is a general purpose column for semi volatiles, pesticides, PCB congeners and essential oils with enhanced selectivity for selected groups of compounds such as isomeric polycyclic aromatic hydrocarbons.
The columns are highly stable with a maximum operating temperature limit (MOTL) of 360°C. They demonstrate unmatched selectivity when compared to conventional stationary phase columns. The NSP-5 columns show ultra low bleed at the retention times of heavier compounds, such as heavier PAH’s.
Due to high temperature stability, these columns can be used in isothermal or temperature program modes up to 360°C. The MOTL decreases with increase in column length and film thickness.
Application Chromatograms
The application chromatograms highlight novel performance demonstrations of J & K’s NSP-5 GC columns. Analyses with application chromatograms of various samples under different conditions on NSP-5 columns of different dimensions are for your review and to evaluate your next GC column purchase.
| NSP-5 | |
|---|---|
| EPA Method 8270 Semi-volatile CLP 44 component mixture by GC-FID, ACN: 148 | ACN: 21154-0015-09-148 |
| EPA Method 8270 Semi-volatile CLP 64 component mixture by GC-FID, ACN: 149 | ACN: 21154-0015-10-149 |
| EPA Method 8270 Semi-volatile CLP mixtures by GC-MSD, ACN:144 | ACN: 21157-0025-09-144 |
| Fast C8-C40 Hydrocarbons, TPHs on NSP-5 column with GC/FID: ACN-141 | ACN : 21124-0010-07-141 |
| Complete resolution of 18 PAH in < 11 min. on NSP-5 column, GC-MS: ACN-140 | ACN : 21124-0010-03-140 |
| Fast PAH GC column , splitless mode NSP-5 Short 0.18 mm ID column: ACN-139 | ACN : 21155-0018-03-139 |
| Ultra fast GC (<5 min.) of EPA Method 610 PAH on NSP-5 Column: ACN-137 | ACN : 21124-0010-03-137 |
| Complete resolution of 18 PAH on NSP-5, 12 mL x 0.15 mm ID column: ACN-136 | ACN : 21124-0010-03-136 |
| Fast GC of priority PAH on NSP-5 short 0.25 mm ID column: ACN-135 | ACN : 21127-0010-03-135 |
| EPA Method 8270 Semi-volatile CLP 81 component mixture by GC-FID, ACN: 150 | ACN: 21154-0015-11-150 |
| EPA Method 8270 Semi-volatile CLP 44 component mixture by GC-FID, ACN: 145 | ACN 21155-0018-10-145 |
| EPA Method 8270 Semi-volatile CLP 64 Component mixture | ACN: 21155-0018-10-146 |
| EPA Method 610 Polycyclic Aromatic Hydrocarbons NSP–5 Column | ACN: 21157-0025-03-152 |
| EPA Method 8270 Semi-volatile CLP 44 Component mixture | ACN: 21157-0025-09-153 |
| EPA Method 8270 Semi-volatile CLP 44 Component mixture | ACN: 21157-0025-09-154 |
| EPA Method 8270 Semi-volatile CLP 44 Component mixture | ACN: 21157-0025-09-155 |
| EPA Method 610 Polycyclic Aromatic Hydrocarbons NSP–5 Column | ACN: 21207-0025-03-156 |
| EPA Method 610 Polycyclic Aromatic Hydrocarbons NSP–5 Column | ACN: 21053-0010-03-157 |
| EPA Method 8270 Semi-volatile CLP 44 Component mixture | ACN: 21053-0010-09-158 |
| EPA Method 610 Polycyclic Aromatic Hydrocarbons NSP–5 Column | ACN: 21154-0015-03-159 |
| EPA Method 8040A Phenols Mixture NSP–5 Column | ACN: 21154-0015-13-160 |
| EPA C8 to C40 Aliphatic Hydrocarbons mixture | ACN: 21124-0010-07-161 |
| EPA Method 610 Polycyclic Aromatic Hydrocarbons NSP–5 Column | ACN: 21157-0025-03-174 |
| EPA Method 610 Polycyclic Aromatic Hydrocarbons NSP–5 Column | ACN: 21157-0025-03-175 |
| EPA Method 610 Polycyclic Aromatic Hydrocarbons NSP–5 Column | ACN: 21154-0015-03-176 |
| EPA Method 610 Polycyclic Aromatic Hydrocarbons NSP–5 Column | ACN: 21154-0015-03-177 |
| Part No. | Length (m) | ID (mm) | Film (µm) | ||
|---|---|---|---|---|---|
| NSP-5 - 2110-10010 | 10 | 0.10 | 0.10 | ||
| NSP-5 - 2110-10015 | 10 | 0.10 | 0.15 | ||
| NSP-5 - 2112-15010 | 12 | 0.15 | 0.10 | ||
| NSP-5 - 2112-15015 | 12 | 0.15 | 0.15 | ||
| NSP-5 - 2112-18015 | 12 | 0.18 | 0.15 | ||
| NSP-5 - 2112-18018 | 12 | 0.18 | 0.18 | ||
| NSP-5 - 2115-15010 | 15 | 0.15 | 0.10 | ||
| NSP-5 - 2115-15015 | 15 | 0.15 | 0.15 | ||
| NSP-5 - 2115-18015 | 15 | 0.18 | 0.15 | ||
| NSP-5 - 2115-18018 | 15 | 0.18 | 0.18 | ||
| NSP-5 - 2115-18035 | 15 | 0.18 | 0.35 | ||
| NSP-5 - 2115-25015 | 15 | 0.25 | 0.15 | ||
| NSP-5 - 2115-25025 | 15 | 0.25 | 0.25 | ||
| NSP-5 - 2115-25050 | 15 | 0.25 | 0.50 | ||
| NSP-5 - 2115-25100 | 15 | 0.25 | 1.00 | ||
| NSP-5 - 2115-32025 | 15 | 0.32 | 0.25 | ||
| NSP-5 - 2115-53050 | 15 | 0.53 | 0.50 | ||
| NSP-5 - 2115-53100 | 15 | 0.53 | 1.00 | ||
| NSP-5 - 2120-15010 | 20 | 0.15 | 0.10 | ||
| NSP-5 - 2120-15015 | 20 | 0.15 | 0.15 | ||
| NSP-5 - 2120-18015 | 20 | 0.18 | 0.15 | ||
| NSP-5 - 2120-18018 | 20 | 0.18 | 0.18 | ||
| NSP-5 - 2120-18035 | 20 | 0.18 | 0.35 | ||
| NSP-5 - 2120-25015 | 20 | 0.25 | 0.15 | ||
| NSP-5 - 2120-25025 | 20 | 0.25 | 0.25 | ||
| NSP-5 - 2120-25050 | 20 | 0.25 | 0.50 | ||
| NSP-5 - 2120-25100 | 20 | 0.25 | 1.00 | ||
| NSP-5 - 2120-32025 | 20 | 0.32 | 0.25 | ||
| NSP-5 - 2120-53050 | 20 | 0.53 | 0.50 | ||
| NSP-5 - 2120-53100 | 20 | 0.53 | 1.00 | ||
| NSP-5 - 2130-18015 | 30 | 0.18 | 0.15 | ||
| NSP-5 - 2130-18018 | 30 | 0.18 | 0.18 | ||
| NSP-5 - 2130-18035 | 30 | 0.18 | 0.35 | ||
| NSP-5 - 2130-25015 | 30 | 0.25 | 0.15 | ||
| NSP-5 - 2130-25025 | 30 | 0.25 | 0.25 | ||
| NSP-5 - 2130-25050 | 30 | 0.25 | 0.50 | ||
| NSP-5 - 2130-25100 | 30 | 0.25 | 1.00 | ||
| NSP-5 - 2130-32025 | 30 | 0.32 | 0.25 | ||
| NSP-5 - 2130-53050 | 30 | 0.53 | 0.50 | ||
| NSP-5 - 2130-53100 | 30 | 0.53 | 1.00 |