Liquid Crystal
J & K has developed a line of liquid crystal polysiloxane (LCP) stationary phases. This technology is unique to J & K. Columns produced with this stationary phase exhibit:
- exceptionally high thermal stability
- a high upper temperature limit
- a wide applicable temperature range
- and a high molecular shape selectivity
The combination of high selectivity and high column efficiency, results in the superb separation of isomeric compounds. These columns are ideal for the separations of isomeric PAHs, Dioxins, PCBs, and naphthalenes as well as group separation, and matrix separation in biological and environmental samples.
Once again, J & K Scientific has raised the bar on column selectivity. Custom made columns can be manufactured by contacting us with your requirements.
Application Chromatograms
- exceptionally high thermal stability
- a high upper temperature limit
- a wide applicable temperature range
- and a high molecular shape selectivity
The combination of high selectivity and high column efficiency, results in the superb separation of isomeric compounds. These columns are ideal for the separations of isomeric PAHs, Dioxins, PCBs, and naphthalenes as well as group separation, and matrix separation in biological and environmental samples.
Once again, J & K Scientific has raised the bar on column selectivity. Custom made columns can be manufactured by contacting us with your requirements.
Application Chromatograms
| ICB-PAH | |
|---|---|
| Complete resolution of critical pairs of EPA method 610 PAH on ICB-PAH: ACN-351 | ACN: 63127-0015-02-351 |
| Resolution of 26 PAH including EPA Method 610 PAH and trhiphenylene on ICB-PAH : ACN-352 | ACN: 63127-0015- 14-352 |
| Comparison of Resolution of triphenylene, Benzo [j] fluoranthene on 3 differnet columns: ACN-301 | ACN: 60043-0010-03-301 |
| Narrow Bore Column Analysis of 16 PAH in Less Than 5 Minutes | ACN:63063-0010- 06-357 |
| EPA Method 610 Polycyclic Aromatic Hydrocarbons ICB – 610 HT Column | ACN: 63103-0010- 06-356 |
| LC-50 | |
|---|---|
| Shape selectivity of LC-50 microbore column for isomer specific separations: ACN-300 | ACN : 60103-0010-03-300 |
| Comparison of Resolution of triphenylene, Benzo [j] fluoranthene on 3 differnet columns: ACN-301 | ACN : 60043-0010-03-301 |
| Resolution of triphenylene, Benzo [j] fluoranthene on 4 meter microbore LC-50 columns: ACN-302 | ACN: 60043-0010-02-302 |
| Resolution of 2,3,7,8-Chlorosubstituted dioxins on a 10 m LC-50 column: ACN-303 | ACN: 60103-0010-13-303 |
| Analysis of Mono- to Octa-chlorodibenzo-p-dioxins on microbore LC-50 column: ACN-304 | ACN: 60207-0010-06-304 |
| Shape selectivity of LC-50 conventional 0.25 mm ID column: ACN-305 | ACN: 60206-0010-06-305 |
| Shape selectivity of LC-50 conventional 0.18 mm ID column: ACN-306 | ACN: 60206-0010-06-306 |
| Part No. | Length (m) | Internal Diameter (I.D.) mm | Film µm | ||
|---|---|---|---|---|---|
| ICB-PAH - 6310-10010 | 10 | 0.10 | 0.10 | ||
| ICB-PAH - 6310-15010 | 10 | 0.15 | 0.10 | ||
| ICB-PAH - 6312-18012 | 12 | 0.18 | 0.12 | ||
| ICB-PAH - 6312-25015 | 12 | 0.25 | 0.15 | ||
| LC-50 - 6005-10010 | 5 | 0.10 | 0.10 | ||
| LC-50 - 6005-15010 | 5 | 0.15 | 0.10 | ||
| LC-50 - 6010-10010 | 10 | 0.10 | 0.10 | ||
| LC-50 - 6010-15010 | 10 | 0.15 | 0.10 | ||
| LC-50 - 6010-18010 | 10 | 0.18 | 0.10 | ||
| LC-50 - 6010-25010 | 10 | 0.25 | 0.10 | ||
| LC-50 - 6015-18010 | 15 | 0.18 | 0.10 | ||
| LC-50 - 6015-25010 | 15 | 0.25 | 0.10 |
Contact us for custom made columns of your desired dimensions and for large orders and distributor inquiries. Prices are subject to change without notice.